| 1840 - 908 pages
...and half the length, with the ends rounded, or turned so that the force would pass through the axis. The strength of a pillar with one end round and the...with both ends round, and one with both ends flat. Some additional strength is given to a pillar by enlarging ils diameter in the middle part. The author... | |
| 1840 - 908 pages
...and half the length, with the ends rounded, or turned so that the force would pass through the axis. The strength of a pillar with one end round and the...same dimensions with both ends round, and one with bota ends flat. Some additional strength is given to a pillar by enlarging its diameter in the middle... | |
| Royal Society (Great Britain) - 1843 - 552 pages
...and half the length, with the ends rounded, or turned so that the force would pass through the axis. The strength of a pillar with one end round and the...with both ends round, and one with both ends flat. Some additional strength is given to a pillar by enlarging its diameter in the middle part. The author... | |
| Royal Society (Great Britain) - 1843 - 538 pages
...and half the length, with the ends rounded, or turned so that the force would pass through the axis. The strength of a pillar with one end round and the...with both ends round, and one with both ends flat. Some additional strength is given to a pillar by enlarging its diameter in the middle part. The strength... | |
| Eaton Hodgkinson - 1846 - 224 pages
...ends of the pillar are flat and firmly bedded, than when they are rounded and capable of turning. 5 2nd. The strength of a pillar, with one end round...of a pillar of the same dimensions with both ends rounded, and with both ends flat. Thus, of three cylindrical pillars, all of the same length and diameter,... | |
| Dennis Hart Mahan - 1855 - 446 pages
...pillars are flat, than when they are rounded. " 2d. The strength of a pillar, with one end rounded and the other flat, is the arithmetical mean between...pillars, all of the same length and diameter, the first naving both its ends rounded, the second with one end rounded and one flat, and the third with both... | |
| W.E. WORTHEN - 1857 - 600 pages
...the ends of braces square and not rounded, as has been proposed and adopted by some architects. 2d. The strength of a pillar with one end round and the...of a pillar of the same dimensions, with both ends rounded and both ends flat. 3d. A long uniform pillar, with its ends firmly fixed, whether by discs... | |
| William Ezra Worthen - 1857 - 632 pages
...the ends of braces square and not rounded, as has been proposed and adopted by some architects. 2d. The strength of a pillar with one end round and the...of a pillar of the same dimensions, with both ends rounded and both ends flat. 3d. A long uniform pillar, with its ends firmly fixed, whether by discs... | |
| William Ezra Worthen - 1857 - 650 pages
...the ends of braces square and not rounded, as has been proposed and adopted by some architects. 2d. The strength of a pillar with one end round and the...mean between that of a pillar of the same dimensions, «'ith both ends rounded and both ends flat. 3d. A long uniform pillar, with its ends firmly fixed,... | |
| Dennis Hart Mahan - 1867 - 428 pages
...pillars are flat, than when they are rounded. " 2d. The strength of a pillar, with one end rounded and the other flat, is the arithmetical mean between...three cylindrical pillars, all of the same length ind diameter, the first having both its ends rounded, the second with one end rounded and one flat,... | |
| |