The net results obtained by the installation of lowpressure turbine units may be summarized as follows : "a. An increase of 100 per cent in maximum capacity of plant. " b. An increase of 146 per cent in economic capacity of plant. " c. A saving of approximately... Heat and Thermodynamics - Page 330by Francis M. Hartmann - 1911 - 346 pagesFull view - About this book
| American Institute of Electrical Engineers - 1910 - 964 pages
...cent in maximum capacity of plant. b An increase of 1 16 per cent in economic capacity of plant. < A saving of approximately 85 per cent of the condensed steam for return of the boilers. d An average improvement in economy of 13 per cent over the best-high pressure turbine... | |
| Joseph Wickham Roe - 1911 - 166 pages
...of plant. "b. An increase of 146% in economic capacity of plant. "c. A saving of approximately 85% of the condensed steam for return to the boilers. "d. An average improvement in economy of 13% over the best HP turbine results. "e. An average improvement in economy of 25% (between limits of 7500... | |
| George Frederick Gebhardt - 1915 - 1022 pages
...addition of lowpressure turbines effected:a. An increase of 100 per cent in maximum capacity of plant. 6. An increase of 146 per cent in economic capacity of...per cent of the condensed steam for return to the boiler. Q*_*r3C»3,t*C*O»-tGO<C ^ ' Lbs. Dry Steam per KWH "*" •— — Act my 'est) EDj Ine .•i... | |
| Robert Heywood Fernald, George Alexander Orrok - 1916 - 626 pages
...Journal, March, 1910. bining a 7,500-kw. Manhattan-type engine with a 7,500-kw. low-pressure turbine. (a) An increase of 100 per cent, in maximum capacity...of the condensed steam for return to the boilers. (<i) An average improvement in economy of 13 per cent, over the best high-pressure turbine results.... | |
| George Frederick Gebhardt - 1917 - 1086 pages
...in many plants. In this noteworthy installation the addition of the low-pressure turbine effected : a. An increase of 100 per cent in maximum capacity...per cent of the condensed steam for return to the boiler. d. An average improvement in economy of 13 per cent over the best high-pressure turbine results... | |
| Robert Heywood Fernald, George Alexander Orrok - 1927 - 692 pages
...7,500-kw. low-pressure turbine. (a) An increase of 100 per cent. in maximum capacity of plant. (6) An increase of 146 per cent. in economic capacity...of the condensed steam for return to the boilers. (rf) An average improvement in economy of 13 per cent. over the best high-pressure turbine results.... | |
| |