" Must be capable of being disconnected at the power plant, or of being divided into sections, so that in case of fire on the railway route, the current may be shut off from the particular section and not interfere with the work of the firemen. This rule... "
Telegraphic Journal and Monthly Illustrated Review of Electrical Science - Page 293
1891
Full view - About this book

Electric Lighting Specifications for the Use of Engineers and Architects

Earle Abbott Merrill - 1892 - 188 pages
...the poles immediately outside the trolley wire. 3. Capable of being disconnected at the power house, or of being divided into sections, so that in case...protected against contact with all other conductors. Car Wiring. All wires in cars must be run out of reach of the passengers, and shall be insulated with a...
Full view - About this book

Convention

National Electric Light Association. Convention - 1892 - 458 pages
...the poles immediately outside the trolley wire. 3. Capable of being disconnected at the power house, or of being divided into sections, so that, in case...protected against contact with all other conductors. . CAR WIRING. All wires in cars must be run out of reach of the passengers, and shall be insulated with a...
Full view - About this book

Standard Tables for Electric Wiremen: With Instructions for Wiremen and ...

Charles M. Davis - 1893 - 162 pages
...immediately outside of the trolley wire. c. Must be capable of being discon. nected at the po»ver-house, or of being divided into sections, so that, in case of fire on the railway route, the current may 85 d. Must be safely protected against contact with all other conductors. 39. CAE WIRING— a. Must...
Full view - About this book

Electrical Engineer, Volume 17

1894 - 622 pages
...bring disconnected at the power house, or of being divided into sections, so that, in case of flre on the railway route, the current may be shut off...particular section and not interfere with the work of the flreraen in extinguishing the flames. This rule also applies to feeders. 4. Must be safely protected...
Full view - About this book

The Electrical Transmission of Energy: A Manual for the Design of Electrical ...

Arthur Vaughan Abbott - 1895 - 646 pages
...outside the trolley wire. 3. Must be capable of being disconnected at the power-house, or of beingdivided into sections, so that, in case of fire on the railway...the flames. This rule also applies to feeders. 4. Must be safely protected against contact with all other conductors. 152. CAR-WIRING. All wires in cars...
Full view - About this book

Electric Wiring for the Use of Architects, Underwriters, and the Owners of ...

Russell Robb - 1896 - 206 pages
...supports shall also be insulated from the poles immediately outside of the trolley-wire. c. Must be capable of being disconnected at the powerhouse, or...section and not interfere with the work of the firemen. This rule also applies to feeders. d. Must be safely protected against contact with all other conductors....
Full view - About this book

Electric Lighting Specifications

Earle Abbott Merrilol - 1896 - 232 pages
...immediately outside of the trolley wire. c. Must be capable of being disconnected at the power house, or of being divided into sections, so that in case...section, and not interfere with the work of the firemen. This rule also applies to feeders. d. Must be safely protected against contact with all other conductors....
Full view - About this book

Electric Lighting Specifications for the Use of Engineers and Architects

Earle Abbott Merrill - 1896 - 222 pages
...immediately outside of the trolley wire. c. Must be capable of being disconnected at the power house, or of being divided into sections, so that in case...section, and not interfere with the work of the firemen. This rule also applies to feeder?. d. Must be safely protected against contact with all other conductors....
Full view - About this book

New Catechism of Electricity: A Practical Treatise

Nehemiah Hawkins - 1896 - 570 pages
...immediately outside of the trolley wire. c. Must be capable of being disconnected at the power house, or of being divided into sections, so that in case...section and not interfere with the work of the firemen. This rule also applies to feeders. d. Must be safely protected against contact with all other conductors....
Full view - About this book

Transactions of the American Institute of Electrical Engineers

American Institute of Electrical Engineers - 1897 - 710 pages
...will be considered as one insulation. /. Must be capable of being disconnected at the power plant, or of being divided into sections, so that, in case...section and not interfere with the work of the firemen. This rule also applies to feeders. m. Must be safely protected against accidental contact where crossed...